Troubleshooting and diagnosing problems
TESTING YOUR PLANTMAID
To check your PlantMaid is functioning correctly you can do a diagnostic test. Press both buttons together to start the following diagnostic sequence:
- You will hear a beep as the test starts
- The Power (‘Po) value will be displayed – any values less than 10 means the batteries are flat.
- You will see a Pump Check start (‘Pc’), and the pump will turn on for 3 seconds
- You should see water squirting out the outlet (assuming the inlet pipe is inserted into water)
- A pump voltage check is displayed after the pump test – any value below 30 indicates a pump error.
BEEPING AND ERROR CODES
If your PlantMaid is beeping or displaying an error code, refer below:
| Error code | Description | What to do |
|---|---|---|
| Pu | Pump water not detected or reservoir empty | This occurs if the pump has detected that water is not being pumped. Ensure the reservoir is full. This error is a warning that the water reservoir is empty, the PlantMaid is still functioning correctly. Just fill up the reservoir and wait for the PlantMaid to resume its next cycle and this warning will disappear. If you want to test the pump is working, press both buttons together to run a diagnostic test |
| SE | Soil sensor level low | If the soil sensor reading is below 5 it is assumed that there is an issue picking up the soil moisture level. This error only occurs when using the soil sensor watering modes. Check that the soil sensor is inserted fully into the soil and that the soil is compacted around the sensor so that there is an accurate reading. Press the sensor button and look at the Soil Level reading('LE'), it should be between 10-60 for a standard soil reading. |
| bA | Battery Low | When the Battery voltage drops below 2V they should be replaced. To check the Power level ('Po') press both buttons together to run a diagnostic check and display power, any reading below 10 means the batteries are almost flat. The PlantMaid will work with Rechargeable batteries but all rechargeables naturally discharge quickly over a few months, Alkaline batteries are recommended as they will last a few months longer. |
| PE | Pump Error | The pump is not working correctly. Either the pump is broken or the batteries are low. Try replacing the batteries to confirm. |

Note: Ensure that no dirt or particles get into the inlet pipe as these may clog the pump. Ensure you only pump water, do not add liquid fertilizer to the water mixture as these contain particles which could block the pump.
OTHER ITEMS